Services

Calibration for the whole test bench.

Eight measurement disciplines under one roof, delivered in-lab, express or on-site. Every service includes as-found and as-left data, stated uncertainties and a recall reminder before the next due date.

01 / 08

Electrical & DC/LF

The foundation of the lab. Our multifunction reference standards cover DC and low-frequency AC voltage, current and resistance from microvolts to kilovolts, so handheld meters and 8½-digit bench instruments are verified against the same traceable references.

Get a quote
Typical instruments
  • Handheld & bench digital multimeters (3½ to 8½ digit)
  • Clamp meters & current probes
  • Insulation resistance testers
  • Earth / ground resistance testers
  • Loop & RCD testers
  • Process & multifunction calibrators
  • Decade boxes & standard resistors
  • Hipot & safety testers
Parameters & ranges
DC voltage
0 V to 1,000 V
AC voltage
1 mV to 1,000 V, 10 Hz to 1 MHz
DC / AC current
1 µA to 20 A (to 1,000 A with coil)
Resistance
1 mΩ to 1 GΩ
Insulation resistance
100 kΩ to 100 GΩ at up to 5 kV
Capacitance
1 nF to 100 mF
02 / 08

Oscilloscopes

We calibrate digital storage, mixed-signal and handheld oscilloscopes using a dedicated oscilloscope calibrator with leveled sine, fast-edge and timing-marker outputs, checking every channel rather than a sample.

Get a quote
Typical instruments
  • Digital storage & mixed-signal oscilloscopes
  • Handheld & battery-powered scopes
  • Active & passive probes
  • Differential & current probes
Parameters & ranges
Vertical DC gain & offset
1 mV/div to 10 V/div
Bandwidth (−3 dB)
up to 6 GHz
Rise time
≥ 70 ps edges
Timebase accuracy
1 ns/div to 50 s/div
Trigger sensitivity
Edge, internal & external
Input impedance
50 Ω and 1 MΩ
03 / 08

Spectrum & signal analyzers

Spectrum and signal analyzers are verified against the manufacturer performance-test procedure wherever one is published, using power sensors, step attenuators and low-phase-noise sources characterised in-house.

Get a quote
Typical instruments
  • Benchtop & handheld spectrum analyzers
  • Signal & vector signal analyzers
  • EMI receivers
  • Cable & antenna analyzers
Parameters & ranges
Frequency reference accuracy
to 1 × 10⁻¹⁰ via GNSS
Absolute amplitude accuracy
9 kHz to 26.5 GHz
Frequency response
9 kHz to 26.5 GHz
Displayed average noise level
down to −165 dBm/Hz
Reference level & attenuator
0 dB to 70 dB
Phase noise
100 Hz to 10 MHz offset
04 / 08

Signal generators

From audio function generators to microwave vector sources, we check output level accuracy, frequency, spectral purity and modulation against traceable power and frequency standards.

Get a quote
Typical instruments
  • RF & microwave signal generators
  • Vector signal generators
  • Function & arbitrary waveform generators
  • Pulse generators
Parameters & ranges
Output level accuracy
−120 dBm to +20 dBm
Frequency accuracy
1 µHz to 26.5 GHz
Harmonics & spurious
to −80 dBc
AM / FM / ΦM depth
Per manufacturer specification
Waveform amplitude & flatness
1 mVpp to 20 Vpp
Pulse width & rise time
≥ 1 ns
05 / 08

RF power & network analyzers

Power sensors receive full calibration-factor tables across frequency. Network analyzers are verified with characterised verification kits and airlines, so you know the instrument behind your own user calibration is sound.

Get a quote
Typical instruments
  • RF power meters & thermal / diode sensors
  • Vector & scalar network analyzers
  • Fixed & step attenuators
  • Directional couplers & terminations
Parameters & ranges
Power sensor cal factor
10 MHz to 18 GHz
Power meter reference (50 MHz)
1 mW reference
Linearity
−60 dBm to +20 dBm
VNA transmission & reflection
to 20 GHz
Attenuation
0 dB to 110 dB
VSWR / return loss
to 18 GHz
06 / 08

Time & frequency

A GNSS-disciplined rubidium reference gives us a continuous, traceable link to UTC. We use it to calibrate frequency counters, timer/counters and the internal timebases of every instrument that passes through the lab.

Get a quote
Typical instruments
  • Frequency counters & timer/counters
  • OCXO & rubidium reference oscillators
  • GNSS-disciplined frequency standards
  • Stopwatches & timers
Parameters & ranges
Frequency
1 mHz to 26.5 GHz
Reference oscillator offset
to 1 × 10⁻¹¹ (24 h)
Time interval
1 ns to 10⁴ s
Ageing / drift assessment
24 h to 30 day logs
07 / 08

Power supplies & loads

Output accuracy, readback, regulation and ripple for programmable supplies and loads, verified with precision shunts and 6½-digit references under real load conditions.

Get a quote
Typical instruments
  • Linear & switch-mode DC power supplies
  • DC electronic loads
  • Power & harmonic analyzers
  • Battery testers
Parameters & ranges
Voltage set & readback
0 V to 600 V
Current set & readback
0 A to 100 A
Load & line regulation
Per specification
Ripple & noise
20 MHz bandwidth
08 / 08

Temperature & process

For process and field technicians: we calibrate the electrical side of temperature measurement, including thermocouple and RTD simulation, loop current and HART-capable calibrators.

Get a quote
Typical instruments
  • Thermocouple & RTD indicators
  • Temperature simulators
  • Loop & mA calibrators
  • Data loggers
Parameters & ranges
Thermocouple simulation
Types J, K, T, E, N, R, S, B
RTD simulation
Pt100, Pt1000
Loop current
0 mA to 24 mA
mV source & measure
−10 mV to 100 mV

Ranges shown are typical. Best measurement capability depends on the parameter and point; ask us for the uncertainty at your specific test points.

Service options

Choose the turnaround that fits the job.

Fixed, itemised quotes for every option. No hidden handling fees, no minimum order.

Express

48-hour

For instruments holding up a project or a shutdown.

Book express
  • Calibration within 2 working days of receipt
  • Priority bench and engineer allocation
  • Same-day as-found notification
  • PDF certificate on completion
On-site

At your facility

When equipment cannot leave the production floor or rig.

Plan a visit
  • Portable reference standards brought to you
  • Scheduled around your shifts and shutdowns
  • Ideal for 20+ instruments or fixed installations
  • Certificates issued within 3 working days
Beyond the bench

Support for your whole calibration programme.

Adjustment & repair

Out-of-tolerance instruments adjusted to specification. Component-level fault finding and manufacturer repairs coordinated on request.

Calibration management

We maintain your instrument register, due dates and certificate archive, and send a consolidated recall list each month.

Interval reviews

Using as-found history to lengthen intervals on stable instruments and shorten them where drift puts measurements at risk.

Audit support

Measurement-traceability summaries for ISO 9001, ISO/IEC 17025 and customer audits, prepared by the engineers who did the work.

Service FAQ

Before you send it in.

The instrument itself, its power cord and any accessories that form part of the measurement, such as probes or test leads you want checked. Please include the previous certificate if you have one, so we can compare results across intervals.

New instruments usually ship with a factory calibration certificate. Whether that certificate meets your quality system depends on the data it contains and its traceability statement. We are happy to review it and tell you if an independent calibration is worthwhile.

Yes. Tell us the specification, test points or tolerance you need when you request a quote. Where your limits are tighter than the manufacturer specification, we will confirm whether our uncertainty supports a confident pass/fail decision.

Calibration compares the instrument to a reference and reports the measured error and its uncertainty. Verification goes one step further and states whether that error is within a given tolerance. Our certificates include both by default.

Our procedures and quality system are built to the requirements of ISO/IEC 17025:2017. Contact us for the current scope of accreditation and which parameters it covers before ordering, if accredited certificates are a requirement for your contract.

Start a calibration

Not sure which service you need?

Send us the make and model. An engineer will tell you what can be calibrated, to which specification, and how long it will take.